87978797威尼斯(老品牌)有限公司--歡迎您!
Home > Industry application > Application in spin-drier with PI9000 frequency inverter
2018-03
26
Application in spin-drier with PI9000 frequency inverter
Click:19302 Source:
分享到:

1.spin-drier drive

spin-drier include with segregating unit and centrifugal machine, directly drive with AC asynchronous motor, feedstock with low speed, to dehydrate with a high speed; widespread used in papermaking, dyeing and finishing, Food Safe, refine sugarchemical industry etc.The modernization spin-drier need different dehydrate speed in different material,so the speed must be adjustable, to meet the craft need .in the past, it widespread use high-low motor to control, feedstock with low speed, use another motor for high-speed drive, Mechanical-Brake when the speed slow down, which drive system Complexly, high failure rate.Because the high-speed motor is large capacity and heavy inertance of the dewatering tank,The start current is often so big and keep long time that the running rate is too low and the frequency is can’t change.

 


 

2.the feature of the PI9000 sensorless vector VFD

·        At the moment, single motor was control by inverter, feedstock with low speed, to dehydrate with a high speed; but if the VFD use V/F control, it maybe lead to mechanical resonance and lack of torque in a low speed. The PI9000 sensorless vector VFD can asynchronous motor parameter static auto tuning, output rate torque, can effective solve the problem which common inverter is lack of torque in a low speed and mechanical resonance widely frequency adjustment 0-400HZ,150% output torque in a low speed,directly drive, low mechanical resonance,high running rate and low after-sale service

3. PI9000 sensorless vector VFD application in spin-drier parameters set

 

Parameter  code

Function introduce

Parameter value

U0.01

Motor control manner

1

U1.00

Motor type selection

1

U6.10

Stop mode

1

U0.04

Frequency source auxiliary setting

6

UC.00

0-stage speed setting 0X

20

UC.01

1-stage speed setting 1X

50

UC.02

2-stage speed setting 2X

65

UC.03

3-stage speed setting 3X

80

UC.04

4-stage speed setting 4X

100

U0.02

Command source selection

1

U4.00

DI1 terminal function selection

12

U4.01

DI2 terminal function selection

13

U4.02

DI3 terminal function selection

14

U4.03

DI4 terminal function selection

15

UC.19,UC.21,UC.23

012 stage ac/deceleration time selection

3

UC.18UC20UC22

012stage running time T0



REGISTRATION
《POWTRAN user service protocol》

Pre-sales

After-sales

Consult

Consult

0769-22222279

Top